On a Sunday morning, our lab catalog took one request, made as the student account student03. After that, nobody touched the lab. In the afternoon, our instructor tool showed this:

lab                    owner        project       phase             age          RDP              progress
student03-phase6       student03    lab-students  6 AD integration  7 h 48 min   192.168.144.10   ready (4/4)

ready (4/4) means all four markers the lab writes as it builds itself are in. The jump host joined the lab domain at 08:53. The lab vCenter was ready at 10:32, and its Active Directory integration at 10:33. VCF Operations came last, at 11:56, 3 h 18 min after the request.

Behind that RDP address sit a Windows jump host, a domain controller dc01 for the lab domain acme.lab, and four nested ESXi 9.1 hosts. Inside those run the vCenter, on vSAN ESA (Express Storage Architecture) with a distributed switch, and VCF Operations. A complete VCF lab, then, from one request and no further help. Easily the most productive Sunday I’ve spent doing nothing.

This series is about the catalog behind that line. It’s one lab in six phases, generated from one site file, and requested by students and trainers in a VCF Automation 9.1 All Apps organization. If you’ve ever built the same lab by hand twice, read on. First, though, the other way to do it.

Two routes to a nested lab

Tom Fojta’s post Building Nested Labs in VCF Automation 9.1 takes the other route, and it’s well worth reading. He builds a “vPod” by hand in one Supervisor namespace. Then he captures it as a blueprint with VCF Automation 9.1’s namespace capture, and deploys copies from it.

Each vPod has a VyOS router. Its uplink sits on a private VPC subnet, and its downlink on a trunk subnet that carries a VLAN subinterface per lab network. He binds the VLAN subnets to the trunk with SubnetConnectionBindingMaps, but keeps them off the VPC gateway. So the router routes between them, and masquerades their traffic on the way out. A DNAT rule on the VPC gateway reaches the router, which forwards what the lab needs, such as RDP to a jump host.

The ESXi hosts install from the ISO on a VM class with nested virtualisation, and VM Groups set the start-up order. He’s open about the rough edges of 9.1.0: capture leaves out the binding maps, VyOS has no VMware Tools, and guest customisation needs a workaround.

Two of his ideas are now in our catalog, with thanks to Tom. The first is promoteDisksMode: Disabled. It keeps our Windows VMs as linked clones of the image cache, instead of copying about 25 GiB each after power-on. On our domain controller test item, the time from request to domain-joined fell from 17.6 to 15.1 minutes, and guest operations answered 9 minutes sooner. The second is vmkernel9Guest on our blank hosts: their image’s own guest type, at hardware version 22.

Capture a hand-built vPodGenerate from a site file
A lab is defined byThe lab itself, built by hand and capturedA site file and a generator; the blueprints are their output
Network and routingA router VM per lab routes the VLAN subnets, NATs outbound and forwards what comes inVLAN subnets on a trunk, routed by the VPC gateway; NAT and RDP on the VPC
Versions and sizesAs captured; another version is another vPodPicked on the request form
Another platformCarry the images across, or build and capture againA new site file and a property-group sync
UpdatingChange the vPod by hand, capture againChange a script or the generator, release a version
Time to deployCopies of a finished lab: nothing left to buildMinutes for blank hosts; 3 h 15 min to 3 h 30 min when the lab builds its own vCenter and VCF Operations
What a lab carriesWhatever was done by hand, including state no script knowsExactly what the scripts do, logged step by step

Capture wins for a one-off. Build the lab once, the way you like it, and every copy starts from those disks, including the things nobody wrote down. Generating pays off when labs repeat: a copy for every student, a new ESXi build, a move to another platform, many people requesting without help. We had all four, which rather settled it.

What building from code gives us

Versions and sizes at request time

In our catalog, versions and sizes are form fields. From the Phase 6 blueprint, trimmed:

  hostSize:
    type: string
    title: Nested host size
    ...
    default: medium
    oneOf:
      - title: Medium - 16 vCPU / 64 GiB per host
        const: medium
      - title: Large - 32 vCPU / 128 GiB per host
        const: large
...
  release:
    type: string
    title: Software release
    ...
    oneOf:
      - title: "VCF 9.1.0 - ESXi 9.1.0.0200, vCenter 9.1.0.0200, VCF Operations 9.1.0.0400"
        const: vcf-9.1.0

The blueprint then looks up every image and folder as propgroup.nestedLabMedia.releases[input.release].<key>, and works out the namespace quota from the sizes asked for. The lab above was requested with VCF Operations at Small, on a host of its own. It was finished 3 h 18 min after the request, against about four hours at Extra small.

No router VM

Our lab networks are ordinary private VPC subnets. Three binding maps put management, vMotion and vSAN onto the hosts’ trunk subnet as VLANs 1610, 1611 and 1612, following the trunk design from the Pod Papers. The VPC gateway routes them like any other subnet. Here’s a student’s Phase 1 lab on f06, read from the Supervisor a minute after it came up:

namespace ns-student03-pj5nt
dc01-student03    PoweredOn
esx01-student03   PoweredOn
esx02-student03   PoweredOn
esx03-student03   PoweredOn
esx04-student03   PoweredOn
jump-student03    PoweredOn
jump-access   LoadBalancer   10.96.1.153   192.168.144.10   3389/TCP   76s

Six VMs, and not one of them routes. The VPC’s own SNAT takes traffic out. RDP to the jump host comes in through the VPC’s load balancer (jump-access). The shared binaries server lives in another VPC, across the transit gateway. A trace from a jump host to it passes the VPC gateway, 172.30.0.33, then the transit gateway. So there’s no router to patch, no VM without VMware Tools, and nothing extra to capture.

One site file per platform

Everything that differs between platforms sits in one YAML file: region, zone and classes, image IDs, the binaries server and the lab’s address plan. From site-f06.yaml:

  network:
    mask: 255.255.255.224
    mgmt:    {cidr: 172.30.0.32/27, gateway: 172.30.0.33, vlan: 1610}
    vmotion: {cidr: 172.30.0.64/27, gateway: 172.30.0.65, vlan: 1611}
    vsan:    {cidr: 172.30.0.96/27, gateway: 172.30.0.97, vlan: 1612}

A generator writes eight blueprints and two property groups from it. The blueprints carry references instead of site values, and VCF Automation resolves them when a lab is requested. The binding maps take their VLANs from the group, and dc01 takes its image, guest type, VM class, storage and disk mode:

        metadata:
          name: ${'dc01-' + input.labName}
          labels: {app: dc01, role: dc}
        spec:
          imageName: ${propgroup.nestedLabSite.windowsImage}
          guestID: ${propgroup.nestedLabSite.windowsGuestId}
          className: ${propgroup.nestedLabSite.dc.vmClass}
          storageClass: ${propgroup.nestedLabSite.storageClass}
          powerState: PoweredOn
          promoteDisksMode: ${propgroup.nestedLabSite.vmService.windowsPromoteDisksMode}

So a changed site value is a sync, not a new blueprint version. When our binaries server moved to a versioned folder tree, the whole catalog change was six values in two property groups. All eight blueprints regenerated identical, byte for byte. Few things are as quietly satisfying as an empty diff.

A second, made-up site file, with its own region, address plan and VLANs, generates the same eight. They differ from f06’s only in the lab list, the form’s starting values and the sample accounts.

Phases are restore points

The catalog offers one lab at six points in a class. Phase 1 is the jump host, dc01 as a plain Windows server, and four blank hosts with the ESXi installer attached. Phase 2 adds the domain, Phase 3 installed hosts, Phase 4 the lab vCenter and Phase 5 VCF Operations. Phase 6 adds the lab domain as a sign-in source for both.

Each phase holds everything before it, so each one is a restore point. Say a student’s hosts break in the vCenter chapter. The lab is deleted and Phase 4 requested again, and about 1 h 50 min later the student carries on with a working vCenter. On f06, every phase has been requested from scratch, which is all a restore is.

Six phase cards, each holding everything before it: DC build about 5 min, domain about 15 min, ESXi hosts about 20 min, vCenter about 1 h 50 min, VCF Operations about 3 h 15 min, AD sign-in about 3 h 30 min Each phase is the one before it plus one layer, so any phase is a restore point. Times are request to ready on f06.

Every student gets the same lab

Each lab has a VPC of its own, with the same addresses inside it. dc01 is at 172.30.0.34, the jump host at .35, the hosts at .40 to .43, the vCenter at .50 and VCF Operations at .51, all in acme.lab. So the class manual needs no table per seat.

The labs are also kept apart. On f06, two students each requested Phase 1. Each saw only their own deployment, and each got a 404 when opening the other’s by its ID.

Blueprints tested and released like software

The blueprints are build output, and they’re treated that way. The generator refuses to write one that contains a site value, and it can’t be talked round. VCF Automation validates each one. A draft request then deploys an unreleased blueprint as a real lab, before anyone else sees it. Finally, one tool releases all eight as one version and withdraws the previous one. Here are the Phase 6 item’s lines from the 30 September release:

== lab-phase-6-ad-integration (default-project, labname) -> blueprint-nested-esxi-lab-full.yaml 2.1.10, 92527 bytes
   version 2.1.10 request form: custom (dc947b26-b884-4c33-8c41-71a865db34af)
   un-release 2.1.9: 200
   release 2.1.10: 200
   versions now: [('2.1.10', True), ('2.1.9', False), ('2.1.8', False), ('2.1.7', False), ...

That was its 21st version. Every earlier one stays in VCF Automation, so rolling back means releasing an older one. And a running lab keeps the version it was built from.

What the series covers next

The next five posts take the catalog apart:

  • what a catalog like this is for: a class, a demo, a new release side by side, an offline rehearsal and testing tools;
  • the network inside a lab VPC, and how the VPC gateway compares with provider VLANs and a router VM;
  • the six phases, what a student and a trainer each get, and how anyone can tell a lab is ready;
  • inside the blueprint: what a phase is made of, how the lab builds itself, and the pipeline that releases it;
  • making it yours: a new site, a new release, a new size or address plan, and a new lab.

Why this matters outside the lab

A lab defined as code is a product, not a pet. Nobody mourns it when it’s deleted. Anyone allowed can request it, it comes out the same every time, and it moves to another platform or release without anyone repeating clicks.

A training team gets one set of instructions for every seat, and a reset button for every student. A platform team gets its changes as reviewed files and released versions. The same pattern fits anything people need many identical copies of: demo kits, proof-of-concept sandboxes, rehearsal copies of a production design.

Rules learned

  • Capture a lab you need once; generate a lab you need again.
  • Keep every site value in one file, and let the blueprints read it when a lab is requested.
  • Let the VPC route. Binding maps carry the VLANs, and the VPC gateway, its NAT and its load balancer do the rest.
  • Put releases and sizes on the request form, not in a captured image.
  • Make every phase a restore point: a broken lab is simply deleted and requested again.
  • Release blueprints like software: generate, lint, deploy a draft, then release one version of everything.

Broadcom documentation